WEKO3
アイテム
コージェネレーションの高効率熱電変換システムの構築
https://doi.org/10.14988/re.2017.0000015786
https://doi.org/10.14988/re.2017.00000157869a915a26-da13-4a6f-b5b8-02972a031957
名前 / ファイル | ライセンス | アクション |
---|---|---|
r004000130021.pdf (1.1 MB)
|
|
Item type | 報告書 / Research Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-04-28 | |||||
タイトル | ||||||
タイトル | コージェネレーションの高効率熱電変換システムの構築 | |||||
言語 | ja | |||||
タイトル | ||||||
タイトル | コージェネレーション ノ コウコウリツ ネツデン ヘンカン システム ノ コウチク | |||||
言語 | ja-Kana | |||||
タイトル | ||||||
タイトル | Construction of High Efficiency Heat to Power Conversion System | |||||
言語 | en | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Co-generation | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Heat to Power Conversion System | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Rankin Cycle | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Kalina Cycle | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_18ws | |||||
資源タイプ | research report | |||||
ID登録 | ||||||
ID登録 | 10.14988/re.2017.0000015786 | |||||
ID登録タイプ | JaLC | |||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
著者 |
川端, 裕二
× 川端, 裕二× 濱地, 康之× 千田, 二郎× 高良, 伸治× 小野, 泰右× 千田, 衞 |
|||||
著者所属 | ||||||
言語 | ja | |||||
値 | 川端, 裕二 / 同志社大学大学院 | |||||
著者所属 | ||||||
言語 | ja | |||||
値 | 濱地, 康之 / ヤンマー(株) | |||||
著者所属 | ||||||
言語 | ja | |||||
値 | 千田, 二郎 / 同志社大学工学部 | |||||
著者所属 | ||||||
言語 | ja | |||||
値 | 高良, 伸治 / 同志社大学大学院 | |||||
著者所属 | ||||||
言語 | ja | |||||
値 | 小野, 泰右 / ヤンマー(株) | |||||
著者所属 | ||||||
言語 | ja | |||||
値 | 千田, 衛 / 同志社大学工学部 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | From the viewpoint of effective use of energy, a Co-generation system (here after CGS) is considered as one of the significant strategies to achieve energy conservation. In recent year, CGS is introduced to low capacity and low heat to power ratio object such as household use and business place. However, Along with this, the total efficiency through the year become low because of low generating efficiency and low heat to power ratio. For introducing the CGS more effectively to wide range of objects, it is important to improve the total efficiency by recovering the electricity from exhaust heat. So we aim to construct the heat to power conversion system covering the low capacity reciprocal engine. In the first stage, we construct heat to power conversion system using exhaust heat from12.5kW diesel engine. Consequently, in this paper describe about simulation result about optimum cycle and working fluid to recover the electricity from it. In the result, Rankin cycle using water as working fluid is more efficiency than Kalina cycle using ammonia water as working fluid. | |||||
言語 | en | |||||
書誌情報 |
ja : 研究成果報告書(2004年度)(第1分冊) p. 97-102, 発行日 2005-07-29 |
|||||
出版者 | ||||||
出版者 | 同志社大学エネルギー変換研究センター | |||||
言語 | ja | |||||
出版者(英) | ||||||
出版者 | Research Center for Energy Conversion System of Doshisha University | |||||
言語 | en | |||||
権利者情報 | ||||||
権利者名 | 同志社大学エネルギー変換研究センター | |||||
言語 | ja | |||||
権利者名 | Research Center for Energy Conversion System of Doshisha University | |||||
言語 | en | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
日本十進分類法 | ||||||
主題Scheme | NDC | |||||
主題 | 533.1 |