{"created":"2023-07-27T07:46:04.192501+00:00","id":20391,"links":{},"metadata":{"_buckets":{"deposit":"4a8a71ad-a5df-412c-9c16-fc0658a19b73"},"_deposit":{"created_by":20,"id":"20391","owners":[20],"pid":{"revision_id":0,"type":"depid","value":"20391"},"status":"published"},"_oai":{"id":"oai:doshisha.repo.nii.ac.jp:00020391","sets":["4251:8393:8394:8395:8420","8:3372:3812:3837"]},"author_link":["16203","16204","16205","15597"],"item_1693811493084":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_1694490770713":{"attribute_name":"権利者情報","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"DA03974933","nameIdentifierScheme":"AID"}],"rightHolderNames":[{"rightHolderLanguage":"ja","rightHolderName":"同志社大学理工学研究所"},{"rightHolderLanguage":"en","rightHolderName":"Science and Engineering Research Institute of Doshisha University"}]}]},"item_1_biblio_info_14":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009-01-31","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"192","bibliographicPageStart":"[187]","bibliographicVolumeNumber":"49","bibliographic_titles":[{"bibliographic_title":"同志社大学理工学研究報告","bibliographic_titleLang":"ja"},{"bibliographic_title":"The Science and Engineering Review of Doshisha University","bibliographic_titleLang":"en"}]}]},"item_1_description_12":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We developed a capillary electrophoresis–chemiluminescence detection system, using a novel PTFE detection cell. The detection cell is comprised of a T-type micro-flow line (0.5 mm i.d.), in which the reaction of luminol-hydrogen peroxide-metal ion catalyst is used to generate chemiluminescence. The two reagent solutions, hydrogen peroxide and metal ion catalyst solution, are delivered toward the T-junction from the two ends of the T-type line positioned on a straight line. A fused silica capillary is inserted through the T-junction into the flow line where the sample eluted from the capillary outlet is mixed with the reagent solutions. In the direct detection method, luminal was determined based on the positive chemiluminescence peak at concentrations over the ranges of 1×10-5–1×10-3 M and 1×10-6–3×10-5 M for Fe(II) and Cu(II) catalysts, respectively. In the indirect detection method, antioxidants were detected based on negative chemiluminescence response; catechin mixture was determined over the concentration range of 3×10-5–1×10-3 M. The indirect detection method using the present system was applied to analysis of catechin in commercial green tea beverages.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_1_description_25":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_1_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.14988/pa.2017.0000011530","subitem_identifier_reg_type":"JaLC"}]},"item_1_publisher_15":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"同志社大学理工学研究所","subitem_publisher_language":"ja"}]},"item_1_publisher_16":{"attribute_name":"出版者(英)","attribute_value_mlt":[{"subitem_publisher":"Science and Engineering Research Institute of Doshisha University","subitem_publisher_language":"en"}]},"item_1_relation_24":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_language":"ja","subitem_relation_name_text":"掲載刊行物所蔵情報へのリンク / Link to Contents"}],"subitem_relation_type":"isFormatOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doors.doshisha.ac.jp/opac/opac_link/bibid/SB00960326/?lang=0","subitem_relation_type_select":"URI"}}]},"item_1_source_id_17":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"00368172","subitem_source_identifier_type":"PISSN"}]},"item_1_source_id_19":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00165868","subitem_source_identifier_type":"NCID"}]},"item_1_subject_27":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"433.4","subitem_subject_scheme":"NDC"}]},"item_1_text_9":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Suzuki, Kosuke / Department of Chemical Engineering and Materials Sciences, Faculity of Engineering, Doshisha University"},{"subitem_text_language":"en","subitem_text_value":"Hashimoto, Masahiko / Department of Chemical Engineering and Materials Sciences, Faculity of Engineering, Doshisha University"},{"subitem_text_language":"en","subitem_text_value":"Tsukagoshi, Kazuhiko / Department of Chemical Engineering and Materials Sciences, Faculity of Engineering, Doshisha University"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Yanagiuchi, Misa","creatorNameLang":"en"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Suzuki, Kosuke","creatorNameLang":"en"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Hashimoto, Masahiko","creatorNameLang":"en"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"Tsukagoshi, Kazuhiko","creatorNameLang":"en"}],"nameIdentifiers":[{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2009-02-03"}],"displaytype":"detail","filename":"023049040001.pdf","filesize":[{"value":"145.7 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"023049040001.pdf","url":"https://doshisha.repo.nii.ac.jp/record/20391/files/023049040001.pdf"},"version_id":"2a908a98-c035-4c2b-aa4e-4d9db6a352f4"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Capillary electrophoresis","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"chemiluminescence","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"antioxidant","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Development of Capillary Electrophoresis Equipped with a Novel PTFE Cell for Chemiluminescence Detection","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development of Capillary Electrophoresis Equipped with a Novel PTFE Cell for Chemiluminescence Detection","subitem_title_language":"en"}]},"item_type_id":"1","owner":"20","path":["3837","8420"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2009-02-02"},"publish_date":"2009-02-02","publish_status":"0","recid":"20391","relation_version_is_last":true,"title":["Development of Capillary Electrophoresis Equipped with a Novel PTFE Cell for Chemiluminescence Detection"],"weko_creator_id":"20","weko_shared_id":-1},"updated":"2023-11-30T07:04:56.958420+00:00"}