{"created":"2023-07-27T07:29:41.563039+00:00","id":165,"links":{},"metadata":{"_buckets":{"deposit":"5e101370-424e-4c68-b5ec-c258f09f1d78"},"_deposit":{"created_by":20,"id":"165","owners":[20],"pid":{"revision_id":0,"type":"depid","value":"165"},"status":"published"},"_oai":{"id":"oai:doshisha.repo.nii.ac.jp:00000165","sets":["4040:4092:4095","4251:8316:8317:8320"]},"author_link":["285","195"],"control_number":"165","item_1693812954976":{"attribute_name":"出版者タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_1694491173138":{"attribute_name":"権利者情報","attribute_value_mlt":[{"rightHolderNames":[{"rightHolderLanguage":"ja","rightHolderName":"同志社大学エネルギー変換研究センター"},{"rightHolderLanguage":"en","rightHolderName":"Research Center for Energy Conversion System of Doshisha University"}]}]},"item_2_alternative_title_2":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Image Analysis of Submicron Particles Based on Satio-temporal Controlled Coherence of Optical System","subitem_alternative_title_language":"en"}]},"item_2_biblio_info_14":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005-07-29","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"48","bibliographicPageStart":"43","bibliographic_titles":[{"bibliographic_title":"研究成果報告書(2004年度)(第1分冊)","bibliographic_titleLang":"ja"}]}]},"item_2_description_12":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"To obtain clear images of sub-micron particles, a procedure for the reduction of wavelength of light and apodization of optical system is adopted to improve resolution, while the imaging resolution is increased with controlling the spatio-temporal coherence of light. The particle miniaturization and composition are advancing rapidly to realize higher particle function so as to add simple optical image and shape analysis of the sub-micron particles. The imaging of profile of submicron particles has been obtained by reducing the light and luminescence wavelength width. The experimental results show that the proposed method is effective for the image analysis of sub-micron class particles.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_2_description_26":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_2_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.14988/re.2017.0000015777","subitem_identifier_reg_type":"JaLC"}]},"item_2_publisher_15":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"同志社大学エネルギー変換研究センター","subitem_publisher_language":"ja"}]},"item_2_publisher_16":{"attribute_name":"出版者(英)","attribute_value_mlt":[{"subitem_publisher":"Research Center for Energy Conversion System of Doshisha University","subitem_publisher_language":"en"}]},"item_2_subject_28":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"571.2","subitem_subject_scheme":"NDC"}]},"item_2_text_8":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_language":"ja","subitem_text_value":"楠澤, 英夫 /共同研究員, シスメックス株式会社"},{"subitem_text_language":"ja","subitem_text_value":"高野, 頌/ コア研究員, 同志社大学工学部物質化学工学科"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"楠澤, 英夫","creatorNameLang":"ja"},{"creatorName":"クスザワ, ヒデオ","creatorNameLang":"ja-Kana"},{"creatorName":"Kusuzawa, Hideo","creatorNameLang":"en"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"高野, 頌","creatorNameLang":"ja"},{"creatorName":"タカノ, ヒロシ","creatorNameLang":"ja-Kana"},{"creatorName":"Takano, Hiroshi","creatorNameLang":"en"}],"nameIdentifiers":[{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2008-04-28"}],"displaytype":"detail","filename":"r004000130012.pdf","filesize":[{"value":"1.7 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"r004000130012.pdf","url":"https://doshisha.repo.nii.ac.jp/record/165/files/r004000130012.pdf"},"version_id":"af1b4997-9587-4faa-8902-0b13bc273a04"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Sub-micron particles","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Image analysis","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Optical coherence","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"research report","resourceuri":"http://purl.org/coar/resource_type/c_18ws"}]},"item_title":"時空間コヒーレント制御光学システムによるサブミクロン粒子の画像解析","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"時空間コヒーレント制御光学システムによるサブミクロン粒子の画像解析","subitem_title_language":"ja"},{"subitem_title":"ジクウカン コヒーレント セイギョ コウガク システム ニヨル サブミクロン リュウシ ノ ガゾウ カイセキ","subitem_title_language":"ja-Kana"}]},"item_type_id":"2","owner":"20","path":["4095","8320"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2008-04-25"},"publish_date":"2008-04-25","publish_status":"0","recid":"165","relation_version_is_last":true,"title":["時空間コヒーレント制御光学システムによるサブミクロン粒子の画像解析"],"weko_creator_id":"20","weko_shared_id":-1},"updated":"2023-11-06T00:42:16.291093+00:00"}